Table top spectrophotometer TS-A12
The table top spectrophotometer TS-A12 features multiple measuring calibers, including the largest caliber of 25.4 mm, catering to the measurement needs of samples of varying sizes. It is capable of accurately measuring the color data of opaque samples, as well as the transmission and opacity of transparent or semi-transparent samples. Equipped with dual light path spectral analysis technology, it ensures precision and long-term stability of the instrument. The 8°/diffused illumination geometric design of lightning provides comprehensive insight into the color data.
Illumination system | d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Size of integrated sphere | 15.2 cm, alvan diffused reflection surface coating |
Illumination light source | CLED |
Sensor | Dual light path sensor array |
Light source | A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF |
Wavelength range | 400-700 nm |
Wavelength interval | 10 nm |
Half spectral width | 5 nm |
Reflectivity range & resolution | 0 to 200%, 0.01% |
Measurement caliber | LAV: large aperture: 2.54 cm (1 inch) MAV: middle aperture: 1.5 cm (0.6 inch) SAV: small aperture: 0.75cm× 1.0 cm (0.3 inch×0.4 inch) VSAV: very small aperture: 0.3 cm× 0.8 cm (0.12 inch× 0.31 inch) |
Measurement time interval | 2 s |
Measurement time | 2 s |
Color space | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, hunterlab, munsell Mi, CMYK |
Color difference formula | ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555 color classification |
Other colorimetric indices | WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint(ASTM E313,CIE,Ganz) Metamerism index Milm, adhesive/changing color fastness, ISO illuminance, 8 gloss, A density, T density |
Repeatability | light splitting reflectivity:standard deviation within 0.08% color values:ΔE*ab<=0.015 ( After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.03 |
Work temperature range | 0 to 45°C, relative humidity 80% or below (at 35°C), no condensation |
Storage temperature range | 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation |
Data being displayed | Samples color values,color difference values/graph,pass/fail results,color error tendency,color value simulation, display measurement area,history data color simulation,manual input standard sample generate measurement report |
Interface | USB |
Display | 5 inch TFT touch screen |
Data storage | 20000 test results |
Light source longevity | 10 years, 3 million tests |
Dimension (L*W*H) | 583 × 330 × 304 mm |
Weight | 18 kg |
- Dual light path spectral analysis technology
- Manual fitting of white calibration board on measurement port
- Four measurement calibers, with the maximum being 25.4 mm
- Large display screen for easier measurement and settings
- Flexible measurement fixtures
- Simultaneous measurement of SCI and SCE
- PC connection for data transmission, software, and storage
- Reflection and transmission measurement capabilities
- Adjustable UV components (light source) percentage value
Tabletop spectrophotometers with multiple measuring calibers are versatile instruments widely used for measuring the color of both solid and liquid materials across various calibration points.